Grideal.com-Leading global industrial mall.
Quick Service for Full HMI Parts Replacement
Touchscreen-Keypad-Display-Case & More Search 80000 Inventory
user photo
Account
Login
Cart
0
Home / All / GUNZE Touch Panel / Other Gunze Series / GT/GUNZE USP 100-4110 Touch Membrane Replacement

GT/GUNZE USP 100-4110 Touch Membrane Replacement

GT/GUNZE USP 100-4110 Touch Membrane Replacement
GT/GUNZE USP 100-4110 Touch Membrane ReplacementGT/GUNZE USP 100-4110 Touch Membrane ReplacementGT/GUNZE USP 100-4110 Touch Membrane ReplacementGT/GUNZE USP 100-4110 Touch Membrane ReplacementGT/GUNZE USP 100-4110 Touch Membrane Replacement
Model100-4110
Warranty365 Days
Product LineGunze 8-Wire
Supply partsTouch Digitizer
Touch Screen Panel TypeResistance touch screen
Shipping2-4 workdays
FOB portGuangzhou, Shenzhen, Hongkong
Terms of PaymentWestern Union, T/T, PayPal, Credit Card
Download
Update Time2026-01-31 01:56:22
Leading Time{{selectedConditionObj.leading}}
{{item.value}}
{{nameObj.name}}{{nameObj.selectedValue}}
{{valueObj.name}}

Shipping

Free Shipping

Those shipping costs are only estimates, the actual shipping cost will be shown on the order page.

Detail Information

Gunze 100-4110 Touch Screen Monitor Repair Replacement

Order each part separately is available

Gunze 100-4110 HMI Panel Glass repair replacement

Answering the demand for lightweight, plastic materials suitable for use in PDAs, Gunze 100-4110 Touch Digitizer combines a Film-Film (F-F) touch panel with a plastic substrate. The electrodes are comprised of 0.1 - 0.2mm thick ITO-coated film. These adhere to a 1 - 2 mm thick plastic substrate. Gunze 100-4110 Touch Panel adjusts the heat expansion coefficients of the polycarbonate material used in its touch panels, overcoming warping problems that can result when plastic is used instead of glass. In addition to being lightweight and fracture-resistant, polycarbonate can be shaped in any way imaginable, enabling design possibilities other than traditional rectangles or squares.


Benefits of Gunze 100-4110 Touch Panels
• Highly durable
• Overlay choices from 2H-9H
• Polycarbonate substrates offer lightweight durability
• Chemically strengthened glass substrates increase impact resistance


Durable materials create a vast array of durable designs. An ideal choice for applications operating in harsh environments or where durability is important:
• Mobile Computing
• Medical Equipment
• Military Equipment
• Aerospace Equipment






Specifications:

Number of Touches:Single
Product Line:GUNZE
Interface:USB / RS232 / COMBO
Warranty:1-Year Warranty
Touch Activation Force:Stylus ≦ 50g
Display Size:4.3 inch
Linearity:X ≦ 1.5%, Y ≦ 1.5%
Tail Options:FFC/ FPC tail
Resolution:320 X 240
Response time:≦ 20ms


Related BB Teach Pendant Part No. :

100-4110Description Inventory status
100-0120Gunze Resistive Touch Screen Glass ReplacementIn Stock
100-0350GUNZE Resistive Touchscreen Panel ReplacementAvailable Now
100-0710Gunze Analog Resistive HMI Panel Glass Repair PartAvailable Now
100-0720/100-072Gunze Analog Resistive HMI Touchscreen Repair PartIn Stock
100-1582GUNZE Resistive HMI Touch Screen Glass RepairAvailable Now
100-1660GUNZE Resistive Touch Screen Panel ReplacementIn Stock
100-1670Gunze Analog Resistive Touch Membrane ReplacementIn Stock
100-1780GUNZE Analog Resistive HMI Touch Glass ReplacementIn Stock
100-3382Gunze Resistive HMI Panel Glass ReplacementAvailable Now
100-4110Gunze Analog Resistive Touch Digitizer Glass RepairAvailable Now
301-4020Gunze Analog Resistive Touch Screen Monitor RepairIn Stock
303-1554GUNZE Resistive HMI Touch Panel ReplacementAvailable Now

GT/GUNZE USP 100-4110 Touch Membrane Replacement PDF Download:

  • Tough Touch Data Sheet
  • Low Reflective Data Sheet
  • High Transmissive Data Sheet
  • Film Glass Data Sheet

  • FAQ:

    Question: Are there any advantages between 4-8 wire vs 5 wire resistive touch panel?

    Answer: 4-8 wire resistive touch panel is the most cost-effective, touch technology to incorporate in your application.

    Question: How many surface treatments finish is available for resistive 100-4110 touch screens?

    Answer: Film surface treatments range from Clear (3H), anti-glare (3H), anti-smudge (3H), anti-reflective (3H) and 4H (size restricted


    Common misspellings:

    100-410

    00-4110

    1004-110

    100-411O

    100-4II0

    1000-4110

    100--4110

    Please send your message to us
    *Email
    Mobile Phone
    *Title
    *Content
    Upload
    • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
    Do you want to quickly know the product quotation you need?
    • Fast QuoteFast Quote
    • Worldwide ShippingWorldwide Shipping
    • 12 Months Warranty12 Months Warranty
    • Customize ServiceCustomize Service
    subscription
    KEEP IN TOUCH
    Please send your message to us
    *Email
    Mobile Phone
    *Title
    *Content
    Upload
    • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
    CONTACT US
    QR code
    Mobile Web
    1.411998s